How to use the P/F ratio calculator
P/F (PaO₂/FiO₂) mode:
- Choose the units your blood gas uses: mmHg or kPa.
- Enter PaO₂ from the arterial blood gas.
- Enter FiO₂ as a percentage (21% is room air).
S/F (SpO₂/FiO₂) mode estimates oxygenation from pulse oximetry when no blood gas is available. Enter SpO₂ (must be 97% or lower) and FiO₂.
The result shows the ratio and where it falls in the commonly used ranges. This is a reference tool for clinicians and students. It does not diagnose ARDS on its own.
Interpreting the P/F ratio
| P/F ratio | Category |
|---|---|
| 400 or more | Normal range |
| 301–399 | Mildly reduced oxygenation |
| 201–300 | Mild ARDS range* |
| 101–200 | Moderate ARDS range* |
| 100 or less | Severe ARDS range* |
*Only when the other Berlin criteria are met, including PEEP or CPAP of at least 5 cmH₂O, timing within one week of a known insult, and bilateral opacities not fully explained by effusions, collapse or nodules.
The 2024 global ARDS definition broadened criteria to include patients on high-flow nasal oxygen (at least 30 L/min) and allows the S/F ratio when blood gases aren’t available, which matters in resource-limited settings.
Worked examples
- PaO₂ 90 mmHg on room air: 90 ÷ 0.21 = 429 (normal)
- PaO₂ 60 mmHg on 40% oxygen: 60 ÷ 0.40 = 150 (moderate range)
- PaO₂ 75 mmHg on 100% oxygen: 75 ÷ 1.0 = 75 (severe range)
- PaO₂ 10 kPa on 50% oxygen: 10 × 7.5 = 75 mmHg → 75 ÷ 0.50 = 150
The third example shows why the ratio matters. A PaO₂ of 75 looks acceptable on its own, but needing 100% oxygen to reach it signals very poor gas exchange.
Why use a ratio rather than PaO₂ alone
PaO₂ depends heavily on how much oxygen the patient is receiving. Dividing by FiO₂ adjusts for that, so oxygenation can be compared across patients and over time as oxygen settings change. It’s simple, but it doesn’t account for PEEP or mean airway pressure. The oxygenation index (OI) does, and is often preferred in pediatric intensive care.
Limitations
- FiO₂ on low-flow devices is an estimate, so the ratio is less precise.
- Altitude lowers PaO₂ for everyone; some clinicians adjust the ratio for barometric pressure.
- The S/F equivalence is approximate and unreliable at saturations above 97% or in patients with poor perfusion.